Section 5 • Fault Codes
5 - 14
GR-20J • GR-26J
Part No. 227656
September 2016
FAULT CODE CHART
Error Source
Error Type
ID
Name
ID
Name
Condition
Solution
16
Diagnostic
display
06
No
communication
The diagnostic display is
not working properly.
Check wire connections. Repair
or replace the diagnostic
display.
Error Source
Error Type
ID
Name
ID
Name
Condition
Solution
70
System
surveillance
Internal system
surveillance has been put
into operation. If the
surveillance detects a
fault in the execution of
this surveillance, this
alarm appears.
It is an internal fault.
Replace the controller.
72
SV1 incorrect
There is a problem
(short-circuit to ground or
to positive) on output
CNE-10.
Check the wiring. If the wiring
is correct and the alarm
persists, there is an internal
fault.
73
SV2 incorrect
There is a problem
(short-circuit to ground or
to positive) on output
CNE-5.
Check the wiring. If the wiring
is correct and the alarm
persists, there is an internal
fault.
74
SV3-4
incorrect
There is a problem
(short-circuit to negative
or to positive) on output
CNE-1 or CNE-3.
Check the wiring. If the wiring
is correct and the alarm
persists, there is an internal
fault.
08
Platform
controls
circuit
board
75
BUSCAN
incorrect
The platform controls
circuit board is not
receiving the CAN signal
from the controller.
There may be an interruption of
the BUSCAN signal. Check the
connection of the BUSCAN
between the modules.
Otherwise, there is an internal
fault in a module which causes
a transmission error, or there is
excessive noise on the
BUSCAN line.
Содержание GR-26J
Страница 12: ...September2016 GR 20J GR 26J Part No 227656 This page intentionally left blank ...
Страница 75: ...Section 4 Repair Procedures Part No 227656 GR 20J GR 26J 4 29 September2016 This page intentionally left blank ...
Страница 109: ...Section 6 Schematics Part No 227656 GR 20J GR 26J 6 3 September2016 ECM Pin out Legend ...
Страница 118: ...Section 6 Schematics 6 12 GR 20J GR 26J Part No 227656 September2016 This page intentionally left blank ...