Switch Fabric and V6.2 Controllers
Slot Controller Setup
3-4
Xedge 6000 Hardware
032R440-000
Installation & Setup Guide
Issue 17
Slot Controller Setup
The following describes the front panel and onboard features of the ACP,
ACS, ECC, ETH, VSM, CE, CHFRC and FRC controllers. Indicators
and jumpers operate in the same manner except where noted. The ACP,
ACS, VSM, ECC controllers have no user-selectable jumpers.
Front Panel Indicators
For ECC Controller Only
•
LINK FAULT
Indicator (ECC only)
Illuminates red when a fault condition exists on one of the associated
LIM link.
•
FLT
Indicator
Illuminates red when a problem prevents the controller from
functioning. Normally off.
•
RUN
Indicator
Illuminates while the controller is powered on and operating.
For ACP, ACS, ETH, VSM, CE, CHFRC and FRC Controllers:
•
FLT
Indicator
Illuminates red when a problem prevents the controller from
functioning. Normally off.
•
RUN
Indicator
Illuminates while the controller is powered on and operating.
•
Link Indicators (
Link 1
,
Link 2
,
Link 3
)
Four groups of Link indicators illuminate as described below.
Link 2 and Link 3 indicators are inactive when the controller is
installed with a two-channel LIM.
RX
Indicator
Flashes yellow when the link is receiving data.
UP
Indicator
Illuminates green while the link is functional.
TX
Indicator
Flashes yellow when the link is transmitting data.
ER
Indicator (Normally off)
ER on while UP is on indicates detection of a line defect.
ER on with UP off indicates a line alarm condition.
ER flashing indicates a LIM fault.
Figure 3-1
Typical Slot Controller Front Panels (Shown: ACP and ECC)
Note
Instead of RX, UP, TX and ER indicators for each link, the ECC Slot Controller has one
LINK FAULT
indicator for all links.
LINK
FLT
ECC
RX
UP
TX
ERR
LINK 0
FLT
RUN
RX
UP
TX
ERR
LINK 1
RX
UP
TX
ERR
LINK 2
RX
UP
TX
ERR
LINK 3
ACS
FLT
RUN