![General DataComm Xedge 6000 Series Скачать руководство пользователя страница 107](http://html1.mh-extra.com/html/general-datacomm/xedge-6000-series/xedge-6000-series_hardware-installation_2210300107.webp)
Line Interface Modules
OC-N / STM-N Overview
032R440-000
Xedge 6000 Hardware
5-5
Issue 17
Installation & Setup Guide
OC-N/STM-N Applications
The OC-N/STM-N LIM with the PCX can be configured to support a variety of LIM applications.
The LIM card is physically divided into two parts of four links each. The following matrix
demonstrates the permitted link locations for each LIM application, including Automatic Protection
Switching (APS) applications.
Note
The limitation of the switch fabric is two OC-3s.
Note
For detailed information on configuring the OC-N/STM-N LIM for use with the PCx Slot Controller, refer to
the Xedge V7x Configuration Guide.
Permitted Link Locations
LIM Applications
Link0 Link1
Link 2 Link 3
Link 4 Link 5
Link 6 Link 7
Eight OC-3s
OC-3 OC-3
OC-3 OC-3
OC-3 OC-3
OC-3 OC-3
Four OC-3s with APS
OC-3 APS
OC-3 APS
OC-3 APS
OC-3 APS
Two OC-3s; One OC-12
OC-3 OC-3
--
--
OC-12
--
--
--
Two OC-3s with APS;
One OC-12 with APS
OC-3 APS
OC-3 APS
OC-12 APS
--
--
Four OC-3s; One OC-12
OC-12
--
--
--
OC-3 OC-3
OC-3 OC-3
Two OC-3s with APS;
One OC-12 with APS
OC-12 APS
--
--
OC-3 APS
OC-3 APS
Two OC-12s with APS
OC-12 APS
--
--