Line Interface Modules
DSX-1 and E1 IMA/IMA+ LIM Overview
032R440-000
Xedge 6000 Hardware
5-39
Issue 17
Installation & Setup Guide
Optional T1/E1 8-Port Break-out Cable Assembly
One T1/E1 8-port Break-out Cable Assembly (S-032H016-001) is used for each front panel 50-pin
Telco connector of an Xedge IMA LIM (E1 or DSX1).
shows the P9 pinouts for the
the upper LIM connector (Links 0 - 7). Pinouts at both LIM connectors are listed in
Table 5-16
.
Figure 5-21
Optional Cabling: T1/E1 8-Port Break-out Cable Assy
Note
IMPORTANT! For all IMA applications, refer to
Class A EMI-RFI Suppression Requirements
) to comply with all domestic and international standards.
1
2
3
4
5
6
7
8
8-Port Break-out Panel
Connector
Housing
T1/E1 Cable Assy
(P/N S-032H016-001)
Retaining
Screw
Cable
DSX1 or E1 LIM
50-PIN
P9
1
26
2
27
3
28
4
29
5
30
6
31
7
32
8
33
9
34
PORT 1
1 Rx 1 Ring
2 Rx 1 Tip
4 Tx 1 Ring
5 Tx 1 Tip
3 (NC)
6 (NC)
50-PIN
P9
10
35
11
36
12
37
13
38
14
39
15
40
16
41
17
42
18
43
50-PIN
P9
19
44
20
45
21
46
22
47
23
48
24
49
25
50
(NC)
(NC)
PORT 2
1 Rx 2 Ring
2 Rx 2 Tip
4 Tx 2 Ring
5 Tx 2 Tip
3 (NC)
6 (NC)
PORT 3
1 Rx 3 Ring
2 Rx 3 Tip
4 Tx 3 Ring
5 Tx 3 Tip
3 (NC)
6 (NC)
PORT 4
1 Rx 4 Ring
2 Rx 4 Tip
4 Tx 4 Ring
5 Tx 4 Tip
3 (NC)
6 (NC)
PORT 5
1 Rx 5 Ring
2 Rx 5 Tip
4 Tx 5 Ring
5 Tx 5 Tip
3 (NC)
6 (NC)
PORT 6
1 Rx 6 Ring
2 Rx 6 Tip
4 Tx 6 Ring
5 Tx 6 Tip
3 (NC)
6 (NC)
PORT 7
1 Rx 7 Ring
2 Rx 7 Tip
4 Tx 7 Ring
5 Tx 7 Tip
3 (NC)
6 (NC)
PORT 8
1 Rx 8 Ring
2 Rx 8 Tip
4 Tx 8 Ring
5 Tx 8 Tip
3 (NC)
6 (NC)
P9
PORTS 1-8
PORTS 9-16