![General DataComm Xedge 6000 Series Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/general-datacomm/xedge-6000-series/xedge-6000-series_hardware-installation_2210300032.webp)
Xedge Chassis Systems
Xedge 6002 Chassis
2-2
Xedge 6000 Hardware
032R440-000
Installation & Setup Guide
Issue 17
Xedge 6002 Chassis
The Xedge 6002 is a compact, 2-slot chassis with an auto-ranging power supply that automatically
adapts to AC power inputs ranging from 90 to 264VAC. For detailed specifications, refer
to the table below.
Xedge 6002 Technical Specifications
Module Installation
Refer to Chapter 3, Switch Fabric and V6.2 Controllers for procedures on how to properly install
and remove modules in and out of the Xedge 6002 chassis.
Note
IMPORTANT! To avoid equipment damage, install only supported Xedge modules in appropriate slots of the
Xedge 6002 chassis. Refer to
and
before installing any modules.
Table 2-2
Xedge 6002 Chassis Specifications
Xedge 6002 AC Version (P/N 200B010-001)
Input Voltage Range
90 to 264 VAC (universal power source)
Input Frequency
47 to 63 Hz
Maximum Power Consumption
150 W
Fuse Rating
1.6A Fast Blow 250V
Dimension (H x W x D):
1.74 in (44.09 mm) x 19.0 in (482.60 mm) x 19.0 in (482.60 mm)
Temperature, operating
32 to 122 deg. F (0 to 50 deg. C)
Temperature, non-operating
-40 to 158 deg. F (-40 to70 deg. C)
Humidity
Up to 95% without condensation
Altitude, operating
0 to 10,000 ft (0 to 3,047 m)
Altitude, non-operating
0 to 40,000 ft (0 to 12,191 m)
Compliance
CISPR 22 Class A, FCC 15 Class A, EN55022, EN5524
UL Listed (UL60950)
c-UL Listed (CSA C22.2 #950)
TUV licensed (EN60950)
CE Mark