![General DataComm Xedge 6000 Series Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/general-datacomm/xedge-6000-series/xedge-6000-series_hardware-installation_2210300040.webp)
Xedge Chassis Systems
Xedge 6160 Chassis
2-10
Xedge 6000 Hardware
032R440-000
Installation & Setup Guide
Issue 17
Front/Rear Panel Features
The front of the Xedge 6160 chassis can hold one switch fabric module and up to four slot controller
modules (slots 0 through 3). The Xedge 6160 is supplied with an electrostatic discharge (ESD) wrist
strap that attaches to the front panel jack on the chassis.
The rear of the chassis can accept up to four LIMs and one System Management Module (SMM),
which provides two management (CRAFT) ports. There are two slots for Power Supply Units (main
and optional) that can provide power supply redundancy. The Power Input connector is not field
replaceable.
Figure 2-2
Xedge 6160 Chassis, Front and Rear Views
Note
IMPORTANT! All empty slots must have blank panels installed and the Power Input Modules must be
installed at all times to maintain proper chassis cooling, EMI shielding, ESD protection, and safety
requirements.
Note
One rear panel slot is intended for the SMM. Refer to Chapter 7, System Management Modules for details
POWER SUPPLY
OPTIONAL
POWER SUPPLY
MAIN
PIM
SLOT 3 LIM
SLOT 2 LIM
SLOT 1 LIM
SLOT 0 LIM
SMM
ESD
Strap
3
2
1
0
SF
SLOT 3
Slot Controller Module
SLOT 2
Slot Controller Module
SLOT 1
Slot Controller Module
SLOT 0
Slot Controller Module
Switch Fabric
Rear View
Front View
Connector for
Antistatic Wrist Strap
Mounting
Brackets