![General DataComm Xedge 6000 Series Скачать руководство пользователя страница 153](http://html1.mh-extra.com/html/general-datacomm/xedge-6000-series/xedge-6000-series_hardware-installation_2210300153.webp)
032R440-000
Xedge 6000 Hardware
7-1
Issue 17
Installation & Setup Guide
Chapter 7:
System Management Modules
Overview
The Xedge System Management Module (SMM) plugs into a special slot on the back panel of the
Xedge 6160 or Xedge 6280 chassis. The SMM provides two craft ports for system management and
an alarm port for external alarm monitoring. The front panel features a serial port lock with
removable key and alarm LEDs for monitoring the Xedge system status. This chapter describes
installing the Xedge SMM in a Xedge 6160 or 6280 switch.
Installation Guidelines
•
When handling the SMM, always use an antistatic wrist strap to prevent static discharge
damage to the electronic circuits.
•
There are no user-configurable jumpers or switches on the SMM card.
•
SMMs can only be installed in the reserved slots shown in
.
•
Once the SMM is installed and connected as described in this section, no further configuration
is necessary.
Installation Procedure
The SMM plugs into a dedicated slot on the rear panel of a Xedge 6280 or Xedge 6160 switch.
These are the only slots that have female connectors that will accept the male pins on the SMM
connectors. Do not attempt to plug an SMM into any other slot.
•
For the Xedge 6160, install the SMM at the bottom slot at the rear of the chassis.
•
For the Xedge 6280, install the SMM at the third slot from the bottom at the rear of the chassis.
Figure 7-1
Proper SMM Locations
Note
IMPORTANT! Use only the specially designated slots listed above for each chassis model. Attempting to
insert the SMM in an incorrect slot can cause damage to the SMM connector or chassis midplane connector.
B POWER SUPPLY
STANDBY
A POWER SUPPLY
STANDBY
B POWER SUPPLY
MAIN
A POWER SUPPLY
MAIN
PIM B
PIM A
SLOT 6 LIM
SLOT 5 LIM
SLOT 4 LIM
SLOT 3 LIM
SLOT 2 LIM
SLOT 1 LIM
SLOT 0 LIM (Main)
SLOT 0 LIM (Standby)
SMM
NTM
POWER SUPPLY
OPTIONAL
POWER SUPPLY
MAIN
PIM
SLOT 3 LIM
SLOT 2 LIM
SLOT 1 LIM
SLOT 0 LIM
SMM
XEDGE 6160 Chassis
(Rear View)
SMM
Xedge 6280 Chassis
(Rear View)
SMM