Line Interface Modules
Class A EMI-RFI Suppression Requirements
032R440-000
Xedge 6000 Hardware
5-43
Issue 17
Installation & Setup Guide
Class A EMI-RFI Suppression Requirements
With the DS3-2C, E3-2C and 155E-2 LIMs, be sure to comply with all domestic and international
Class A EMI-RFI suppression requirements by installing the proper ferrite beads on the TX and RX
cables, as shown in the figures below. Note that ferrite bead type and placement varies depending
on the Xedge chassis in use.
Note
IMPORTANT! The TX and RX cables must use the Belden Coaxial Cable, P/N 9054 or equivalent. Slot/LIM
applications in the Xedge 6002 may require additional ferrite beads. Consult your Xedge representative.
Xedge 6640, 6645, 6280 and 6160 Chassis Only
Figure 5-25
LIM Class A EMI-RFI Suppression in Xedge High Density Chassis
Xedge 6002 1RU Chassis Only
Figure 5-26
LIM Class A EMI-RFI Suppression in the Xedge 6002 Chassis
5" max
LIM Front Panel
(side view)
Ferrite bead
P/N 232-005-004
(3 for each TX/RX port)
Belden Coax cable
P/N 9054 (or equivalent)
Xedge 6002 Chassis
(Shown with Xedge PCX Slot Controller)
A
C
B
D
5" max
DS3, E3 or 155E LIM
Front Panel
D
Ferrite bead
P/N 232-005-004
(3 for each TX/RX port)
Belden
coax cable (2)
5" max
Slot Controller
Front Panel
Ferrite bead
P/N 232-008-014
(1 for each port)
cable
B,C
5" max
Xedge Chassis
Front Panel
Ferrite bead
P/N 232-008-015
looped cable
A