Additional Features
Monitoring Features
5-8
SpectraComm SDT
076R174-000
Installation and Operation Manual
Issue 4
Monitoring Features
Each System Message or Alarm log entry is time-stamped with a relative System Up Time (default)
or with GMT, if so configured (refer to
in this chapter).
System Message Log
The System Message log shows a history of the last 100 SYS MSG events saved to the log. Use this
log to examine link status, diagnostic test activity, etc. The System Message log is not saved when
the unit reboots.
•
To show the last 100 logged events, type:
show log sysmsg
•
To clear the log, type:
clear log sysmsg
Figure 5-3
Example: System Message Log
Alarm Log
The Alarm log shows a history of the last 100 Alarm events saved to the log. The Alarm log is not
saved when the unit reboots.
•
To show the last 100 logged alarms, type:
show log alarm
•
To clear the log, type:
clear log alarm
Figure 5-4
Example: Alarm Log