Application Guidelines
General Application Information
A-4
SpectraComm SDT
076R174-000
Installation and Operation Manual
Issue 4
fallback
Controls fallback to local
authentication
Enable or
Disable
server
Defines the server IP
address.
Server IP address (a.b.c.d)
Per-server key: Quoted string, 72 chars
max (optional)
Per-server timeout (optional)
(Default is no server specified)
key
Sets a default
encryption key
Quoted string, 72 char max
(No default)
timeout
The interval the device will wait for
the server to respond
before trying the next server on the
list.
1 to 10 seconds,
5
Configure Time
Controls the use of Simple
Network Time Protocol (RFC2030)
and Time Protocol (RFC 868)
Enable or
Disable
Note: When configured for SNTP or TP, the device will receive and use
Greenwich Mean Time (GMT) to timestamp any generated SNMP traps, System
Messages and Alarms. When neither SNTP nor TP is configured, the device will
use a relative System Up Time for timestamping.
Time protocol
Selects the time protocol
SNTP1, SNTP2,
SNTP3
, SNTP4 or TP
Time server
Defines the time server IP
address.
Time server IP address (a.b.c.d)
Per-server NTP version 1-4 (optional)
(Default is no server specified)
Table A-1
Configuration Parameters and Defaults
Configurable Option
Description
Parameters and Defaults