HYDRAULIC PUMP INSTALLATION
STEP 9
G0905113
Install a new gasket on the pump mounting flange.
STEP 10
G0905114
Align the pump input shaft (1) with the gear drive (2)
i n t h e tr a n s m i s s i o n . S l i d e th e s h a ft i n t o t h e
transmission until the mounting flange contacts the
transmission.
STEP 11
G0905115
Install the two pump mounting bolts. Tighten the bolts
to a torque of 80 to 90 lb.-ft. (110 to 122 Nm).
STEP 12
Remove the plugs from the pump output hoses and
the caps from the pump fittings.
STEP 13
G0905106
Connect the output hoses to the hydraulic pump.