10.5.1.1 Removing the control top
Fig.19
Requirement:
•
No solenoid valve must be actuated electrically or manually.
•
The pneumatic and electrical connections on the plant side can remain on the
control top.
Caution!
The permanent magnet on the switch bar is fragile.
Damage to the permanent magnet.
► Protect the permanent magnet against impact stress.
Tools required:
•
Hex socket key
Carry out the following steps:
1.
Remove snap rings (1) from the control top (B).
2.
Detach the pneumatic connection from the actuator.
3.
Pull off the control top (B) upwards.
Maintenance
Disassembling the valve
430BAL013307EN_8
46
04.08.2022