Carry out the following steps:
1.
Check that the union nut on the cable gland is tight
2.
Check that the cable connections are firmly secured.
3.
Check the solenoid valves for proper function.
4.
Check that the proximity switch connections are clean.
®
Done
Hint!
The electrical cable must be long enough to allow the control top to be
removed via the switch bar.
10.2.4 Signs on the valve
Carry out the following steps:
1.
Check the signs on the valve.
2.
Replace damaged or missing stickers with new ones.
®
Done
10.3
Servicing intervals
To ensure the highest operational reliability of the valves, all wearing parts should
be replaced at longer intervals. Keep an adequate supply of wearing parts (stem
diaphragms and seals) in your spare parts stock.
In practice, the actual maintenance intervals can only be determined by the user
since they depend on the operating conditions.
Examples of relevant process parameters are:
•
daily period of use,
•
switching frequency,
•
type and temperature of the product,
•
type and temperature of the cleaning solution,
•
ambient conditions.
If there is still no or too little information available for the definition of practically-
orientated maintenance intervals, the reference values listed in the following table
can be considered as a basis. The following information is based on the
experience of GEA Flow Components and applies to installations working in a 2-
shift operation.
Hint!
Prior to any work on the open valve, ensure that it has stopped
operation, see section Section 10.4, Page 45
Maintenance
Servicing intervals
430BAL013307EN_8
04.08.2022
43
Содержание D-tec D
Страница 66: ...Fig 39 Maintenance Assembling the valve 430BAL013307EN_8 66 04 08 2022...
Страница 69: ...Fig 41 Maintenance Assembling the valve 430BAL013307EN_8 04 08 2022 69...
Страница 85: ...Fig 55 Housing Parts list D tec double chamber valve type D DV 430BAL013307EN_8 04 08 2022 85...
Страница 91: ...Fig 58 hard seal Parts list D tec valve insert D DV SV NC NO 430BAL013307EN_8 04 08 2022 91...
Страница 95: ...15 Parts list lift actuator _LB DV Fig 59 Parts list lift actuator _LB DV 430BAL013307EN_8 04 08 2022 95...
Страница 99: ...Fig 61 Dimension sheet double chamber valve type D DV 430BAL013307EN_8 04 08 2022 99...
Страница 105: ...Appendix 430BAL013307EN_8 04 08 2022 105...
Страница 106: ......