10.6.2 Assembling the main valve
Fig.40
Requirement:
•
No solenoid valve must be actuated electrically or manually.
•
The pneumatic and electrical connections on the plant side can remain on the
control top.
Spring-closing valve NC
Warning!
Spring tension in the valve
A risk of injury exists due to incorrectly installed clamp connections (43)
when the valve is vented as the spring tension that is released suddenly lifts
the actuator.
► Ensure that the clamp connections (43) have been assembled correctly
before venting.
Maintenance
Assembling the valve
430BAL013307EN_8
04.08.2022
67