STEP 4—CONFIGURE THE REMOTE RADIO
The instructions below summarize essential Remote settings for
tabletop testing. For detailed log-in and menu navigation instructions,
see
CHAPTER 4 REMOTE RADIO MANAGEMENT,
beginning on
Page 99
.
Log-in and Configuration
Prepare the Remote for configuration as follows:
1. Connect a PC to the
COM1
port on the radio.
2. Establish a terminal session (using HyperTerminal, for example)
using the following data parameters:
• 19200 bps
• 8 bits
• no parity
• one stop bit (8N1)
Table 2-1. Key AP Parameters and Defaults
Menu Item
Management System Loca-
tion
Default
Values or Range
IP Address
Main Menu >> Network
Configuration > IP
Configuration
192.168.1.1
Contact your Network
Administrator.
If
IP Address Mode
(below) is set
to Dynamic,
IP Address
is
configured automatically.
IP Address
Mode
Main Menu >> Network
Configuration > IP
Configuration
Static
Static | Dynamic
IP Netmask
Main Menu >>
Network Configuration > IP
Configuration
255.255.0.0
Settable per customer
requirements
Net Address
Main Menu >>
Network Configuration >
Wireless MAC Configuration
9999
1-15 alphanumeric characters*
RF Output
Power
(non-ETSI)
Main Menu >>
Radio Configuration >
900 MHz: 30 dBm
2.4 GHz: 27 dBm
900 MHz: 20–30 dBm
2.4 GHz: 17-27 dBm
RF Output
Power (ETSI)
Main Menu >>
Radio Configuration >
2.4 GHz: 20 dBm
2.4 GHz: 10-20 dBm
Password
Changes
Main Menu >>
Security Configuration >
User Passwords
Administrator Password:
admin
(lower case)
Guest Password:
guest
(lower case)
• 1–8 alphanumeric characters
• Passwords are case sensitive;
can be mixed case
* We recommend setting Net Address to the last four digits of the AP serial number to reduce the chance of conflict
with other nearby entraNET systems.
Содержание MDS entraNET 900
Страница 10: ...LA N CO M1 CO M2 PW R LIN K viii MDS entraNET Technical Manual 05 4055A01 Rev E...
Страница 12: ...2 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 24: ...14 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 26: ...16 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 38: ...28 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 110: ...100 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 130: ...120 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 156: ...146 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 158: ...148 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 176: ...166 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 186: ...176 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 188: ...178 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 204: ...194 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 218: ...I 8 MDS entraNET Technical Manual 05 4055A01 Rev E...
Страница 220: ...GE MDS LLC Rochester NY 14620 General Business 1 585 242 9600 FAX 1 585 242 9620 Web www gemds com 175 Science Parkway...