05-4055A01, Rev. E
MDS entraNET Technical Manual
105
DEFAULT=<mode>
—Sets or displays the
COM1
port default mode on
startup.
DEFAULT
cannot be set to
DATA
unless the device has been
authorized for serial payload.
CONSOLE
:
COM1
defaults to command-line mode.
DATA
:
COM1
defaults to transparent data mode.
BSP
:
COM1
defaults to in Basic Serial Protocol mode.
INT_LOOP
:
COM1
defaults to internal loopback mode.
EXT_LOOP
:
COM1
defaults to external loopback mode.
FORMAT=<format>
—Sets or displays the
COM1
port data characters,
parity, and stop bits setting. Valid data parameters are:
7N1
—seven char bits, no parity, one stop bit
7N2
—seven char bits, no parity, two stop bits
7O1
—seven char bits, odd parity, one stop bit
7O2
— seven char bits, odd parity, two stop bits
7E1
—seven char bits, even parity, one stop bit
7E2
—seven char bits, even parity, two stop bits
8N1
—eight char bits, no parity, one stop bit (default setting)
8N2
—eight char bits, no parity, two stop bits
8O1
—eight char bits, odd parity, one stop bit
8O1
—eight char bits, odd parity, two stop bits
8E1
—eight char bits, even parity, one stop bit
8E2
—eight char bits, even parity, two stop bits
NOTE:
Entering data formats other than those listed above might
cause undesired operation.
GROUP=<ID>
—
Sets or displays the Group ID that this transceiver
belongs to at the AP, for purposes of serial data multicasting (0-15).
INTERGAP=
—
Sets or displays the transceiver inter-packet gap status.
Optional arguments:
IO
—For incoming and outgoing serial data.
IN
—For incoming serial data only.
IOL
—For incoming and outgoing (low latency) serial data.
INL
—For incoming (low latency) serial data only.
MODE=<mode>
—Sets the console port interface mode.
MODE
cannot be
set to
DATA
unless the device has been authorized for serial payload. To
escape from data mode, enter three conse characters to
COM1,
with at least 100 ms between entries.
CONSOLE
—Places
COM1
in command-line mode.
DATA
—Places
COM1
in transparent data mode.
BSP
—Places
COM1
in Basic Serial Protocol mode.
INT_LOOP
—Places
COM1
in internal loopback mode.
EXT_LOOP
—Places
COM1
in external loopback mode.
Содержание MDS entraNET 900
Страница 10: ...LA N CO M1 CO M2 PW R LIN K viii MDS entraNET Technical Manual 05 4055A01 Rev E...
Страница 12: ...2 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 24: ...14 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 26: ...16 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 38: ...28 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 110: ...100 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 130: ...120 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 156: ...146 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 158: ...148 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 176: ...166 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 186: ...176 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 188: ...178 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 204: ...194 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 218: ...I 8 MDS entraNET Technical Manual 05 4055A01 Rev E...
Страница 220: ...GE MDS LLC Rochester NY 14620 General Business 1 585 242 9600 FAX 1 585 242 9620 Web www gemds com 175 Science Parkway...