104
MDS entraNET Technical Manual
05-4055A01, Rev. E
APLIST
Configures a list of approved APs.
Optional arguments:
APx=<integer>
—Configures a list of approved APs.
x
is a number from
1–50, and
integer
is the serial number of an approved AP (1–99999999).
To delete an entry, enter a serial number of 0; this indicates that the slot
is not filled.
AP1=<integer>
Serial Number of approved AP
AP2=<integer>
Serial Number of approved AP
.
.
.
AP50=<integer>
Serial Number of approved AP
CLEAR
—Clears all entries in the AP list. Set
RESTRICT
to
OFF
before
using this command to avoid restricting Remotes to associating with an
empty list.
CMD
—Displays all settable optional arguments and their current values.
You can copy this list to a text file as a record of your configuration.
RESTRICT=<ON|OFF>
—Turns on or off restricting registration to APs in
the list.
ON
—The Remote can only associate with an AP on the list.
OFF
—The Remote can associate with any AP.
AUTH
Displays the list of authorized features, or changes the Authorization
Key that controls these features.
Optional arguments:
KEY=<key>
—Enter a valid authorization key (1–16 characters), which is
used to enable or disable software features.
(Example:
AUTH KEY=123456abcdef
)
CMD
—Displays all settable optional arguments and their current values.
You can copy this list to a text file as a record of your configuration.
COM1
Optional arguments:
BAUD=<bps>
—Sets or displays the baud rate setting as 1200, 2400, 4800,
9600, 19200, 38400, 57600, or 115200 bps.
BUFFER=<bytes>
—Sets or displays the maximum
COM1
port buffer size
(1–1500).
CMD
—Displays all settable optional arguments and their current values.
You can copy this list to a text file as a record of your configuration.
Содержание MDS entraNET 900
Страница 10: ...LA N CO M1 CO M2 PW R LIN K viii MDS entraNET Technical Manual 05 4055A01 Rev E...
Страница 12: ...2 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 24: ...14 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 26: ...16 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 38: ...28 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 110: ...100 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 130: ...120 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 156: ...146 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 158: ...148 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 176: ...166 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 186: ...176 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 188: ...178 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 204: ...194 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K...
Страница 218: ...I 8 MDS entraNET Technical Manual 05 4055A01 Rev E...
Страница 220: ...GE MDS LLC Rochester NY 14620 General Business 1 585 242 9600 FAX 1 585 242 9620 Web www gemds com 175 Science Parkway...