2-10
F35 MULTIPLE FEEDER PROTECTION SYSTEM – INSTRUCTION MANUAL
ORDER CODES
CHAPTER 2: PRODUCT DESCRIPTION
2
2.3.2 Order codes with process bus modules
Table 2-6: F35 order codes for horizontal units with process bus
CONTACT INPUTS/OUTPUTS
XX
XX
XX No Module
4A
4A
4A 4 Solid-State (no monitoring) MOSFET outputs
4B
4B
4B 4 Solid-State (voltage with optional current) MOSFET outputs
4C
4C
4C 4 Solid-State (current with optional voltage) MOSFET outputs
4D
4D
4D 16 Contact inputs with Auto-Burnishing (maximum of three modules within a case)
4L
4L
4L
14 Form-A (no monitoring) Latching outputs
67
67
67
8 Form-A (no monitoring) outputs
6A
6A
6A 2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 contact inputs
6B
6B
6B 2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 contact inputs
6C
6C
6C 8 Form-C outputs
6D
6D
6D 16 Contact inputs
6E
6E
6E
4 Form-C outputs, 8 contact inputs
6F
6F
6F
8 Fast Form-C outputs
6G
6G
6G 4 Form-A (voltage with optional current) outputs, 8 contact inputs
6H
6H
6H 6 Form-A (voltage with optional current) outputs, 4 contact inputs
6K
6K
6K 4 Form-C and 4 Fast Form-C outputs
6L
6L
6L
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 contact inputs
6M
6M
6M 2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 contact inputs
6N
6N
6N 4 Form-A (current with optional voltage) outputs, 8 contact inputs
6P
6P
6P
6 Form-A (current with optional voltage) outputs, 4 contact inputs
6R
6R
6R 2 Form-A (no monitoring) and 2 Form-C outputs, 8 contact inputs
6S
6S
6S
2 Form-A (no monitoring) and 4 Form-C outputs, 4 contact inputs
6T
6T
6T
4 Form-A (no monitoring) outputs, 8 contact inputs
6U
6U
6U 6 Form-A (no monitoring) outputs, 4 contact inputs
6V
6V
6V 2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching outputs, 8 contact inputs
TRANSDUCER INPUTS/OUTPUTS
(select a maximum of 3 per unit)
5A
5A
5A 4 DCmA inputs, 4 DCmA outputs (only one 5A module is allowed)
5C
5C
5C 8 RTD inputs
5D
5D
5D 4 RTD inputs, 4 DCmA outputs (only one 5D module is allowed)
5E
5E
5E
4 RTD inputs, 4 DCmA inputs
5F
5F
5F
8 DCmA inputs
INTER-RELAY
COMMUNICATIONS
(select a maximum of 1 per unit)
For the last module, rear slot P is used for digital and transducer
input/output modules; rear slot R is used for inter-relay
communications modules.
2A C37.94SM, 1300 nm single-mode, ELED, 1 channel single-mode
2B C37.94SM, 1300 nm single-mode, ELED, 2 channel single-mode
2E
Bi-phase, single channel
2F
Bi-phase, dual channel
2G IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
2H IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
2I
Channel 1 - IEEE C37.94, MM, 64/128 kbps; Channel 2 - 1300 nm, single-mode, Laser
2J
Channel 1 - IEEE C37.94, MM, 64/128 kbps; Channel 2 - 1550 nm, single-mode, Laser
72
1550 nm, single-mode, Laser, 1 Channel
73
1550 nm, single-mode, Laser, 2 Channel
74
Channel 1 - RS422; Channel 2 - 1550 nm, single-mode, Laser
75
Channel 1 - G.703; Channel 2 - 1550 nm, single-mode Laser
76
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 1 Channel
77
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels
7A 820 nm, multimode, LED, 1 Channel
7B 1300 nm, multimode, LED, 1 Channel
7C 1300 nm, single-mode, ELED, 1 Channel
7D 1300 nm, single-mode, Laser, 1 Channel
7E
Channel 1 - G.703; Channel 2 - 820 nm, multimode
7F
Channel 1 - G.703; Channel 2 - 1300 nm, multimode
7G Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED
7H 820 nm, multimode, LED, 2 Channels
7I
1300 nm, multimode, LED, 2 Channels
7J
1300 nm, single-mode, ELED, 2 Channels
7K 1300 nm, single-mode, Laser, 2 Channels
7L
Channel 1 - RS422; Channel 2 - 820 nm, multimode, LED
7M Channel 1 - RS422; Channel 2 - 1300 nm, multimode, LED
7N Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, ELED
7P
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, Laser
7Q Channel 1 - G.703; Channel 2 - 1300 nm, single-mode Laser
7R G.703, 1 Channel
7S
G.703, 2 Channels
7T
RS422, 1 Channel
7W RS422, 2 Channels
F35
- * **
- * * * - F **
- H **
- M **
- P **
- U **
- W/X **
Full Size Horizontal Mount
BASE UNIT
F35
|
|
| |
|
|
|
|
|
|
|
Base Unit
CPU
T |
| |
|
|
|
|
|
|
|
RS485 and Three Multi-mode fiber 100Base-FX (SFP with LC)
U |
| |
|
|
|
|
|
|
|
RS485 and Two Multi-mode fiber 100Base-FX (SFP with LC), One 10/100Base-TX
(SFP with RJ45)
V |
| |
|
|
|
|
|
|
|
RS485 and Three 10/100Base-TX (SFP with RJ45)
SOFTWARE OPTIONS
00
| |
|
|
|
|
|
|
|
No Software Options
01
| |
|
|
|
|
|
|
|
Ethernet Global Data (EGD)
03
| |
|
|
|
|
|
|
|
IEC 61850
04
| |
|
|
|
|
|
|
|
Ethernet Global Data (EGD) and IEC 61850
A0
| |
|
|
|
|
|
|
|
CyberSentry Lvl 1
A1
| |
|
|
|
|
|
|
|
CyberSentry Lvl 1 and Ethernet Global Data (EGD)
A3
| |
|
|
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850
A4
| |
|
|
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850 and Ethernet Global Data (EGD)
AW
| |
|
|
|
|
|
|
|
CyberSentry Lvl 1 and IEC 61850 and PID controller
B0
| |
|
|
|
|
|
|
|
IEEE 1588
B1
| |
|
|
|
|
|
|
|
IEEE 1588 and Ethernet Global Data (EGD)
B3
| |
|
|
|
|
|
|
|
IEEE 1588 and IEC 61850
B4
| |
|
|
|
|
|
|
|
IEEE 1588 and IEC 61850 and Ethernet Global Data (EGD)
BW
| |
|
|
|
|
|
|
|
IEEE 1588 and IEC 61850 and PID controller
C0
| |
|
|
|
|
|
|
|
Parallel Redundancy Protocol (PRP)
C1
| |
|
|
|
|
|
|
|
PRP and Ethernet Global Data
C3
| |
|
|
|
|
|
|
|
PRP and IEC 61850
C4
| |
|
|
|
|
|
|
|
PRP, Ethernet Global Data, and IEC 61850
CW
| |
|
|
|
|
|
|
|
PRP, PID controller, and IEC 61850
F35
- * **
- * * * - F **
- H **
- M **
- P/R **
Reduced Size Vertical Mount (see note regarding P/R slot below)
Содержание F35
Страница 12: ...1 4 F35 MULTIPLE FEEDER PROTECTION SYSTEM INSTRUCTION MANUAL FOR FURTHER ASSISTANCE CHAPTER 1 INTRODUCTION 1 ...
Страница 202: ...4 88 F35 MULTIPLE FEEDER PROTECTION SYSTEM INSTRUCTION MANUAL FLEXLOGIC DESIGN USING ENGINEER CHAPTER 4 INTERFACES 4 ...
Страница 562: ...6 30 F35 MULTIPLE FEEDER PROTECTION SYSTEM INSTRUCTION MANUAL PRODUCT INFORMATION CHAPTER 6 ACTUAL VALUES 6 ...
Страница 576: ...7 14 F35 MULTIPLE FEEDER PROTECTION SYSTEM INSTRUCTION MANUAL TARGETS CHAPTER 7 COMMANDS AND TARGETS 7 ...
Страница 650: ...A 38 F35 MULTIPLE FEEDER PROTECTION SYSTEM INSTRUCTION MANUAL FLEXANALOG ITEMS APPENDIX A FLEXANALOG OPERANDS A ...
Страница 658: ...C 6 F35 MULTIPLE FEEDER PROTECTION SYSTEM INSTRUCTION MANUAL COMMAND LINE INTERFACE APPENDIX C COMMAND LINE INTERFACE C ...
Страница 666: ...iv F35 MULTIPLE FEEDER PROTECTION SYSTEM INSTRUCTION MANUAL ABBREVIATIONS ...
Страница 682: ...xvi F35 MULTIPLE FEEDER PROTECTION SYSTEM INSTRUCTION MANUAL INDEX ...