C70 Capacitor Bank Protection and Control System
GE Multilin
2.1 INTRODUCTION
2 PRODUCT DESCRIPTION
2
Table Notes:
1.
RW = read and write access
2.
R = read access
3.
Supervisor = RW (default), Administrator = R (default), Administrator = RW (only if Supervisor role is disabled)
4.
NA = the permission is not enforced by CyberSentry Security
CYBERSENTRY USER AUTHENTICATION
There are two types of authentication supported by CyberSentry that can be used to access the UR device:
•
Device Authentication (local UR device authenticates)
•
Server Authentication (RADIUS server authenticates)
The EnerVista software allows access to functionality that is determined by the user role, which comes either from the local
UR device or RADIUS server.
The EnerVista software has a device authentication option on the login screen for accessing the UR device. When the
"Device" button is selected, the UR uses its local authentication database and not the RADIUS server to authenticate the
user. In this case, it uses its built-in roles (Administrator, Engineer, Supervisor, Observer, Operator, or Administrator and
Supervisor when Device Authentication is disabled) as login names and the associated passwords are stored on the UR
device. As such, when using the local accounts, access is not user-attributable.
In cases where user attributable access is required especially to facilitate auditable processes for compliance reasons, use
RADIUS authentication only.
When the "Server" Authentication Type option is selected, the UR uses the RADIUS server and not its local authentication
database to authenticate the user.
No password or security information are displayed in plain text by the EnerVista software or UR device, nor are they ever
transmitted without cryptographic protection.
|---------------
IEC61850 GOOSE
Integers
RW
RW
R
R
R
|------------
Transducer I/O
RW
RW
R
R
R
|------------
Testing
RW
RW
R
R
R
|------------
Front Panel Labels Designer
NA
NA
NA
NA
NA
|------------
Protection Summary
NA
NA
NA
NA
NA
Commands
RW
RW
RW
R
R
|------------
Virtual Inputs
RW
RW
RW
R
R
|------------
Clear Records
RW
RW
RW
R
R
|------------
Set date and time
RW
RW
RW
R
R
User Displays
R
R
R
R
R
Targets
R
R
R
R
R
Actual Values
R
R
R
R
R
|------------ Front Panel Labels Designer
R
R
R
R
R
|------------ Status
R
R
R
R
R
|------------ Metereing
R
R
R
R
R
|------------ Transducer I/O
R
R
R
R
R
|------------ Records
R
R
R
R
R
|------------ Product Info
R
R
R
R
R
Maintenance
RW
RW
R
R
R
|------------ Modbus Analyzer
NA
NA
NA
NA
NA
|------------ Change Front Panel
RW
RW
RW
R
R
|------------ Update Firmware
Yes
No
No
No
No
|------------ Retrieve File
Yes
No
No
No
No
Roles
Administrator
Engineer
Operator
Supervisor
Observer
Содержание C70
Страница 10: ...x C70 Capacitor Bank Protection and Control System GE Multilin TABLE OF CONTENTS ...
Страница 30: ...1 20 C70 Capacitor Bank Protection and Control System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Страница 394: ...5 270 C70 Capacitor Bank Protection and Control System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 452: ...8 18 C70 Capacitor Bank Protection and Control System GE Multilin 8 1 OVERVIEW 8 THEORY OF OPERATION 8 ...
Страница 474: ...9 22 C70 Capacitor Bank Protection and Control System GE Multilin 9 4 SETTING EXAMPLE 9 APPLICATION OF SETTINGS 9 ...
Страница 486: ...10 12 C70 Capacitor Bank Protection and Control System GE Multilin 10 6 DISPOSAL 10 MAINTENANCE 10 ...
Страница 630: ...B 110 C70 Capacitor Bank Protection and Control System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 676: ...E 10 C70 Capacitor Bank Protection and Control System GE Multilin E 1 OVERVIEW APPENDIX E E ...
Страница 688: ...F 12 C70 Capacitor Bank Protection and Control System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Страница 698: ...H 8 C70 Capacitor Bank Protection and Control System GE Multilin H 3 WARRANTY APPENDIX H H ...