TR-HT2xx LED Controller - User Manual
TT1
to enable the internal trigger using the period last set
TT1,p
to enable the internal trigger and set the period.
Where:
p
= trigger period in milliseconds.
Note :
The
TT1
command does not disable external triggers.
Save the settings to memory
AW
This command saves the settings to non-volatile memory. If you
power cycle the TR-HT before sending the
AW
command, all
changes are lost and the unit returns to the values set before the last
AW
command.
Clear configuration
CL
This command clears the configuration and lighting ratings, and
turns the output off. The results of any
VL
,
RS
,
RW
,
RU
,
RT
,
RE
,
RP
,
TT
, and
AW
commands are cleared.
Show configuration
This command shows the configuration of the TR-HT. Type in:
ST
A typical reply to this command might be:
CH1,MD0,S50.0,0.0,DL1.000ms,PU1.000ms,
RT 0.0us,IP1,FL0,CS0.000A,RA0.000A
CH2,MD0,S50.0,0.0,DL1.000ms,PU1.000ms,
RT 0.0us,IP1,FL0,CS0.000A,RA0.000A
Where:
CH
channel number
MD
mode: 0 = continuous, 1 = pulsed, 2 = switched
S
brightness percentage setting:
First setting used in all modes
Second setting only used for selected mode
DL
pulse delay
PU
pulse width
RT
retrigger delay
IP
input trigger (set using the
RP
command)
—
62
—