TR-HT2xx LED Controller - User Manual
Output channel 2 will not accept a pulse until 10ms after the
previous one.
Set pass or fail
In resync mode, this command returns the pass or fail state of the
image processing for the given trigger tag.
SNc,t,p
Where:
c
=
output channel (1 to 4)
t
=
trigger tag number
p
=
1 = pass, 0 = fail.
For example:
SN1,76,1
Defines trigger tag 76 on output channel 1 as a 'pass'.
Read the encoder count
Use this command to read the encoder count:
EN
This command returns a message in the same form as this example:
VL200
Where 200 is the number of encoder counts received by the
TR-HT since it was turned on. The count is a 32 bit unsigned number
that wraps to 0 when it reaches 2
32
.
Set the encoder mode
Use this command to set the encoder type:
ZEe
Where:
e
= 0 to turn the encoder off,
1 for a one-wire encoder, or
2 for a two-wire encoder.
Set an output
Use this command to set an output to a given logic level:
ZVc,v
Where:
c
= output channel (1 to 4)
—
67
—