TR-HT2xx LED Controller - User Manual
5
Mounting the TR-HT
Mount the TR-HT on a flat surface using M4 screws through the mounting
holes in the unit's case. The illustration below shows the positions of the
mounting holes.
5.1
Environmental considerations
The TR-HT enclosure is a fire enclosure as long as it is mounted so that
none of the connectors are facing downwards.
If a fire enclosure is used, the enclosure should be metal or plastic (with a
flammability rating of UL94 V1 or better) and with no holes below or to the
sides of the TR-HT when mounted. Cable entries below the TR-HT should
be through glands that also have a flammability rating of UL94 V1 or
better. The TR-HT should be at least 10mm from any other part or side of
the enclosure. The TR-HT does not have an IP rating and must be
mounted so that moisture and dirt cannot enter the unit.
—
16
—