TR-HT2xx LED Controller - User Manual
s
=
brightness setting in percent (0 to 999)
r
=
retrigger delay in milliseconds ( 0.1 to 999). This
parameter is optional and if not set, the
minimum allowed retrigger time is set.
Note:
An error message is returned if the brightness setting requires
a greater current than the maximum current output or if the
combination of pulsed width and brightness is not allowed under the
limitations of the unit.
Set the option flags
This command sets the flags for error detection, trigger sense, and
SafeSense:
REc,m
Where
c
= the output channel (1 to 2), and
m
can take the following
values:
m
Error
detection
Trigger sense
SafeSense
0
Enabled
+
Enabled
2
Disabled
+
Enabled
4
Enabled
—
Enabled
6
Disabled
—
Enabled
8
Enabled
+
Disabled
10
Disabled
+
Disabled
12
Enabled
—
Disabled
14
Disabled
—
Disabled
Set the trigger input
This command sets the input used for pulse and switched output
modes.
RP,c,p
Where:
c
=
output channel (1 to 2)
p
=
trigger input (1 to 4).
Set the internal trigger
These commands control the internal trigger. When set, the output
is triggered using an internal trigger signal. Type in:
TT0
to disable the internal trigger
—
61
—