GALA PULSE SYNERGIC DR ADVANCED. Instructions Manual
31
4.3. CYCLE PARAMETERS
–
MIG PROCESS.
From this screen we will adjust the values that define the welding cycle. The cycle graph and parameter selection
table will change based on the welding mode selection.
KEY
ACTION
DESCRIPTION
P1
Return to Source Process
Requests to confirm changes in case of modification.
P2
Access to Operation Mode
It accesses to Selected Process Mode
P3
Gas Purge
P4
Threading of wire
P6
Restore factory settings
Restores original factory settings.
E1
Select parameter
Selected parameter with blank bar.
When browsing the parameter selection table, the
corresponding segment of the upper cycle graph will
illuminate simultaneously.
E2
Modify parameter
Each of the different cycles will be composed of different regulation parameters that will vary depending on the
selected operating mode:
PARAMETER DESCRIPTION
FUNCTION
REMARKS
UNIT
RESOLUTION
FDC
Wire approach speed
It adjusts the approach speed.
%
1
TPR
Pre-gas time
It facilitates the arc ignition
Seconds
0.1
TC
Striking ascent ramp time Softens the arc ignition
Milliseconds
1
IS
Starting intensity
It reduces the striking cracks.
%
1
TIS
Start current time
Carry -out preheating of material
In 2S mode only Seconds
0.1
CCE
U2 Striking Correction
Customise the striking
%
1
DWS1
Ramp Is
I2
It reduces the initial stress
Seconds
0.1
CBP
U2 Correction (l2 High) Arc customising
BIPULSE only
%
1
DBP
Double arc difference
Arc customising - Heat reduction.
%
1
DCL
Time % (l2 High)
It balances the pulse for heat control.
%
1
DWS2
Ramp I2
IE
It reduces the end stress
Seconds
0.1
IE
Final intensity
It reduces the crater cracks.
%
1
TIE
Final intensity time
It reduces the crater size
In 2S mode only Seconds
0.1
TBB
Burn Back Time
Adjust final wire length
Milliseconds
10
TPS
Post-gas time
Prevents bead rust.
Seconds
0.1
CCT
Current Change Time
Transition time between active arc memories
Milliseconds
10