GALA PULSE SYNERGIC DR ADVANCED. Instructions Manual
53
6.4. CYCLE PARAMETERS
–
MMA PROCESS.
From this screen we will adjust the values that define the welding cycle. The cycle graph and parameter selection
table will change based on the welding mode selection.
KEY
ACTION
DESCRIPTION
P1
Return to Source Process
Requests to confirm changes in case of modification.
P2
Access to Operation Mode
It accesses to Selected Process Mode
P6
Restore factory settings
Restores original factory settings.
E1
Select parameter
Selected parameter with blank bar.
When browsing the parameter selection table, the
corresponding segment of the upper cycle graph will
illuminate simultaneously.
E2
Modify parameter
Each of the different cycles will be composed of different regulation parameters that will vary depending on the
selected operating mode:
PARAMETER
DESCRIPTION
FUNCTION
REMARKS
UNIT
RESOLUTION
HS
Hot Start
It facilitates the arc ignition
%
1
Arc force
It reduces the arc
decompensations.
%
1
Inductance
It adjusts the Arc Dynamic
--
--
IB
Base current
Heat reduction.
PULSE only
%
1
DCL
Duty cycle
It balances the pulse for heat
control.
%
1
TCP
Pulse fall time
Softens the I
₂
-IB transition
Milliseconds
10