• With or without "DL" suffix, delayed action closing feature.
• With or without "M" suffix, Metal Cover.
An incorrectly installed or improperly
adjusted door closer can cause property
damage or personal injury. These instructions
should be followed to avoid the possibility
of misapplication or misadjustment.
CAUTION
Non Hold Open
&
Models
Hold Open
Installation Instructions
• Maximum pull side frame reveal is 1/8" (3mm).
• Minimum frame face for pull side is 1-3/8" (35 mm).
• All components are non handed.
• The use of ball bearing hinges is recommended for the door on which the closer will be installed.
Door must swing freely.
• Where severe or abusive conditions are expected a separate door stop, supplied by others, is recommended to
assist in preventing damage to the door closer, closer arm; or to the door, frame or adjacent walls.
• Door and frame must be properly reinforced, or the use of special fasteners employed, to prevent door collapse or
the mounting screws from pulling out.
• All dimensions are given in inches with corresponding metric dimensions (millimeters) in parentheses.
Installation Type
Hing
e Edg
e of Door
Hing
e Edg
e of Door
Push (Stop) Side Mounted
Pull (Hinge) Side Mounted
For Use on Doors with 4½" or 5" (115-127mm) Wide Butt Hinges
•
have 50%
power increase capability. Closer size 4 has the weakest
power, closer size 6 has the strongest power.
•
can be
adjusted from size 1 thru 6.
Sized Door Closers 3340/3540 & 3350/3550
Multi-Sized Closer 3341/3541 & 3351/3551
3040 & 3050 Slide Track Door Closers
80-9303-2212-010 (06-09)
PULL SIDE MOUNTED
PUSH SIDE MOUNTED
3340ST, 3341ST,
3540ST, 3541ST
P3340ST, P3341ST,
P3540ST, P3541ST
The closing force for these series of door
closers is adjustable from a size 1 to a size 6,
as outlined in ANSI Standard A156.4. When
these series of door closers are installed and
adjusted to conform to ADA reduced opening
force rerequirements (5 lbs max.) for interior
doors, they may not have adequate closing
force to reliably close and latch the door. Power adjustments
charted on Page 5 are recommended, where possible, to
insure proper door control.
Left Hand Door-LH
Right Hand Reverse-RHR
Left Hand Door-LH
Right Hand Reverse-RHR
Right Hand Door-RH
Left hand Reverse-LHR
Note: Hold open models are not
permitted to be installed in Listed
fire door assemblies.
Right Hand Door-RH
Left hand Reverse-LHR
Non Hold Open
3350ST, 3351ST,
3550ST, 3551ST
Hold Open
Non Hold Open
Hold Open
P3350ST, P3351ST,
P3550ST, P3551ST
3050 Series Hold Open Units Are Not Permitted To Be Installed In Fire Door Assemblies