GALA PULSE SYNERGIC DR ADVANCED. Instructions Manual
47
PARAMETER
DESCRIPTION
FUNCTION
REMARKS
UNIT
RESOLUTION
VH2
Secondary Wire
Speed
It permits the use of a 2nd wire speed
If WIRE = ON only
%
1
BBH
Time ON wire 1
Brake the wire before switching to I
₂
.
%
1
TPR
Pre-gas time
It facilitates the arc ignition
Seconds
0.1
IS
Start current
It reduces the striking cracks.
%
1
TIS
Start current time
Carry -out preheating of material
2SS Mode only
Seconds
0.1
UPS
Ascent ramp time
It reduces the initial stress
Seconds
0.1
IB
Base current
Heat reduction.
PULSE - BIPULSE
only
%
1
Dcl
Duty cycle
It balances the pulse for heat control.
%
1
TCP
Pulse fall time
Softens the I
₂
-IB transition
Milliseconds
10
DWS
Descent ramp time
It reduces the end stress.
Seconds
0.1
IE
Final current
It reduces the crater cracks.
%
1
TIE
Final intensity time
It reduces the crater size
2SS Mode only
Seconds
0.1
TPS
Post-gas time
Prevents bead rust.
Seconds
0.1
CCT
Current Change Time Transition time between active arc
memories
Milliseconds
10
BIPULSED ARC - CONTINUOUS MODE
2S TORCH MODE
2SS TORCH MODE
4S TORCH MODE
WIRE INPUT = ON
SPOT MODE
ARC
STD
PULSE
2S TORCH MODE