GALA PULSE SYNERGIC DR ADVANCED. Instructions Manual
17
3.5.1.3. 2ND TORCH BUTTON ACTION.
When we use torches that incorporate a double button system, we can choose the action controlled by the secondary
button:
REGULATION E2
DESCRIPTION
Correction We will act on the correction value selected in the equipment.. e.g. Pulsed frequency
Programme Increase or decrease for each press 1 programme from the list of available
programmes.
3.5.1.4. CONTROL CENTER SELECTION.
During the start-up sequence, the equipment assigns a numbering to each of the available controls, by means of
which we can select from where we regulate the equipment.
REGULATION E2
DESCRIPTION
AUT
Automatic selection of highest number available.
Power source < Wire feeder < Remote control.
NoC
Installation with wire feeder without setting panel. Control from power supply panel.
000
Control from power supply panel.
001
Control from wire feeder panel
3.5.1.5. WIRE FEEDING SYSTEM SELECTION.
Allows more precise adjustment of the configuration parameters of the different available wire feeders.
REGULATION E2
DESCRIPTION
WF1
Parameter setting for manual use wire feeders. .
WF2
Parameter setting for robotic installations wire feeders.