4.2.3 MIG PROCESS
–
MANUAL CONTROL (STD + PULSED ARC).
It allows to regulate the wire speed and the welding tension independently of the synergic curve.
KEY
ACTION
DESCRIPTION
P1
Return to Main Menu
P2
Access to Programme Library
P3
Access to Operation Mode / Synergic Programme Selection
P4
Access to Cycle Parameters
It access to the specific cycle of selected mode.
P5
Select Secondary Value
Temporarily places value in leading position.
E1
Modify Main Value
It adjusts the Welding Voltage.
Modify Secondary Value
It adjusts the Welding Dynamic.
E2
Modify Main Value
It adjusts the Wire Speed.