GALA PULSE SYNERGIC DR ADVANCED. Instructions Manual
5
1.1. TECHNICAL FEATURES.
TECHNICAL FEATURES
GPS 4000 DR ADVANCED
GPS 5000 DR ADVANCED
Reference
42381200 42355200 42600200 42650200
Input voltage U1 (3 Ph, 50/60Hz)
400 V
440 V
400 V
440 V
Maximum primary intensity I1max
35 A
32 A
40 A
36 A
Primary effective intensity I1eff
22 A
20 A
27 A
24 A
Maximum Effective Power
24/15 KVA
28/19 KVA
MIG/MAG Regulation Range I2min-I2max
30 ÷ 400 A (45%)
30 ÷ 500 A (45%)
MIG/MAG Welding Intensity DC = 100%
270 A
350 A
Welding Voltage Regulation U2min-U2max
12 ÷ 34 V
12 ÷ 42 V
Applicable Wire Diameters (mm.)
0.8 ÷ 1.6 mm
0.8 ÷ 1.6 mm
Wire speed (m/min.)
1 ÷ 24 m/min
1 ÷ 24 m/min
Wire feeding system
4R – 100 W-Enc
4R – 100 W-Enc
MMA Continuous Regulation Range I2min-I2max
30 ÷ 400 A
30 ÷ 500 A
TIG Continuous Regulation Range I2min-I2max
5 ÷ 400 A
5 ÷ 500 A
Mechanical Protection Index (IP)
IP 23 S
IP 23 S
Ventilation
Forced
Forced
Weight
45 kg.
54.5 Kg
ACCORDING TO UNE-EN 60974. (1) Other power supply voltage values on demand.
GPS DR DIMENSIONS
IS INCLUDED
•
Grounding:
-
400A
→
GPS 4000 DR
-
500A
→
GPS 5000 DR
•
Instructions Manual
1.2. COOLING MODULE - WCS 520. Ref. 65982000.
Recommended for connection extensions up to a max. length of 15 m.
The electrical connection of the equipment is carried out directly to the power source by
an internal connection. For further information, please refer to the cooling module
manual.
ELECTRICAL CONNECTION OF THE COOLING MODULE TO THE POWER SUPPLY.
Open back cover
Carry out the connection
Close the cover