220
Chapter 7 Installing Internal Options
SCSI ID and Order of Installation
The numbers and SCSI IDs of the 3.5-inch storage bays are as follows. The SCSI IDs for internal hard
disk units are set automatically.
Install internal hard disk units in the following order.
7.6.3 How to Install Internal Hard Disk Units
1
Turn off the server and connected devices, and unplug all power cables from
the outlet.
2
Touch a metal part of the server to discharge static electricity.
3
Remove the dummy unit from the bay to accommodate an internal hard disk
unit.
Pull the dummy unit out towards you with its tabs being pressed inward.
Be sure to keep the removed dummy units for later use.
table: Order of Internal Hard Disk Unit Installation
Order of installation
Bay 1
→
Bay 4
→
Bay 2
→
Bay 5
→
Bay 3
Bay1 : ID=0
Bay2 : ID=1
Bay3 : ID=2
Bay4 : ID=0
Bay5 : ID=1
SCSI A-ch (0ch)
SCSI B-ch (1ch)
Press the
tabs inward
Содержание PRIMERGY RX600 S3
Страница 44: ...44 Chapter 1 Overview ...
Страница 58: ...58 Chapter 2 Checking before OS Installation ...
Страница 136: ...136 Chapter 4 Manual OS Installation ...
Страница 180: ...180 Chapter 6 High Reliability Tools ...
Страница 292: ...292 Chapter 9 Operation and Maintenance ...
Страница 304: ...304 ...