24
Chapter 1 Overview
n
System Power button (
)
Press to turn the system power on or off.
`
Do not turn the server off when the Hard disk access LED is blinking.
Data in the hard disk may be damaged.
o
System Reset button (
)
Press to reset and restart the system.
`
Do not restart the system when the Hard disk access LED is blinking.
Data in the hard disk may be damaged.
p
Maintenance button
This button is used for maintenance by your support personnel. Do not operate this button by
yourself.
q
Fan modules
This server has four system fans by default, and a redundant function is effective.
r
Fan module failure LED
Indicates fan modules status. This LED glimmers amber when the server is turned on, and is lit
intense amber at the time of fan modules failure
.
s
3.5-inch storage bay
Contains an internal hard disk.
t
Hard disk access LED ( )
This LED is lit when data is being written to or read from the hard disk. When the hard disk is not
accessed, this is not lit.
u
Hard disk failure LED ( )
During an array system configuration, this LED is lit amber when an error is detected in the
internal hard disk unit. It is lit or blinks depending on the hard disk status as follows.
table: Meaning of the Hard Disk Failure LED
LED
Description
Off
In normal mode or hot spare mode
On (Amber)
Error detected in the hard disk (in an array configuration)
Blinking (Amber)
Rebuilding or faulty hard disk replacement in progress
Содержание PRIMERGY RX600 S3
Страница 44: ...44 Chapter 1 Overview ...
Страница 58: ...58 Chapter 2 Checking before OS Installation ...
Страница 136: ...136 Chapter 4 Manual OS Installation ...
Страница 180: ...180 Chapter 6 High Reliability Tools ...
Страница 292: ...292 Chapter 9 Operation and Maintenance ...
Страница 304: ...304 ...