160
Chapter 5 Operations after OS Installation
BIOS Setup Utility Setting
When power management is performed via a LAN, configure the settings as follows using the BIOS
Setup Utility. This is set to "Enabled" by default.
1
Start the BIOS Setup Utility.
"8.3.1 Starting and Exiting the BIOS Setup Utility" (pg.243)
2
Set [WOL Resume from S5] of the [Server] menu to [Enabled].
3
Press the [F10] key.
The confirmation message whether to save the changes is displayed.
4
Select [Yes] and press the [Enter] key.
`
To start up the server via a LAN, refer to "
Performing Remote Installation" (
5.5.6 Other Notes on Operation
Unnecessary Files
After OS installation is completed, folders named Runonce and Runonce 2 may be left in the drive
where the OS is installed. Delete these folders since you do not need them for the system operation.
Notes on 24-hour Operation
z
Automated System Operation
To provide an extra margin of safety against unintentional damage, introduce disaster-prevention
measures in the office and keep disaster prevention personnel (such as a security guard or janitor) in the
building.
z
Unintentional Power-off Prevention
We recommend the installation of a special power supply device (such as a distribution board) to prevent
unplanned power shut-offs.