192
Chapter 7 Installing Internal Options
15
Install the upper processor air baffle.
Insert the latches on the sides of the baffle into the sides of the server, and then insert the notches
on the front side of the baffle into the front of the server to install the cover.
Install the cable through the sides of the baffle. At this time, make sure that the cable is not
pinched.
16
Connect the removed cables to the original positions.
17
Install the top cover.
7.3.4 Defective CPU Disconnection Function
This server is equipped with a defective CPU disconnection function.
This function disconnects a CPU judged to be defective (abnormal) during Power On Self Test (POST)
to start the server. For example, on two-CPU servers, if one CPU is defective, the other CPU starts up
the server.
The failed CPU can be checked with the information displayed during POST or from Processor menu of
the BIOS Setup Utility.
Replace the defective CPU, if discovered, and then restart the server.
The cable is passed sideward
of the air baffle.
The notches of the air baffle are
inserted in the tabs on a front
side of the server.
Insert the latches into
the sides of the server.
Notches
"Situation seen
from the back"
Содержание PRIMERGY RX600 S3
Страница 44: ...44 Chapter 1 Overview ...
Страница 58: ...58 Chapter 2 Checking before OS Installation ...
Страница 136: ...136 Chapter 4 Manual OS Installation ...
Страница 180: ...180 Chapter 6 High Reliability Tools ...
Страница 292: ...292 Chapter 9 Operation and Maintenance ...
Страница 304: ...304 ...