6. Execute the set telnet enable command to enable telnet.
Administrator> set telnet enable
7. Set the date and time as needed.
Use the following command.
Administrator> set date MMDDhhmm[[CC]YY][,ss]
Example:April 27, 2009 13:10:00 is set as the date and time.
Administrator> set date 042713102009,00
8. After the MMB Ready LED goes on (initialization completed), confirm that the Alarm LED on each unit is
off.
3.3.3
Setting up the connection environment for actual operation
Set up the connection environment for actual operation from the configured test environment by performing the
following:
Setting the IP address of the MMB console PC
Connecting the MMB console PC to the MMB USER port
Connecting the PRIMEQUEST 1000 series server to an external LAN
Setting the IP address of the MMB console PC
Set the IP address of the PC used as the MMB console. For details on how to set it, see the manuals for the PC used.
Connecting the MMB console PC to the MMB USER port
Connect your MMB console PC to MMB USER port#0 with a LAN cable. When connected, the MMB console PC
can communicate with the MMB via the LAN.
FIGURE 3.2 MMB USER port location
Connecting the PRIMEQUEST 1000 series server to an external LAN
The following describes the configuration of external LAN connections of the PRIMEQUEST 1000 series server.
It also describes points to consider about the connections. We recommend you configure security before connecting
an external LAN. For details on security, see
.
PRIMEQUEST 1000 Series Installation Manual
CHAPTER 3 Work before Operating System Installation
23
C122-E107-09EN
Содержание PRIMEQUEST 1000 Series
Страница 1: ...C122 E107 09EN FUJITSU Server PRIMEQUEST 1000 Series Installation Manual ...
Страница 2: ......
Страница 32: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 1 Installation Overview 4 C122 E107 09EN ...
Страница 44: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 2 Preparing for Main Unit Installation 16 C122 E107 09EN ...
Страница 260: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX A Lists of Settings Links 232 C122 E107 09EN ...
Страница 284: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation 256 C122 E107 09EN ...
Страница 340: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server Windows 312 C122 E107 09EN ...
Страница 344: ......