7. Click [Add] in [Trap Send Destination].
Enter the host name or IP address of the server receiving the trap (i.e., the trap destination). Then, click [Add].
Click the [OK] button.
8. Select [Action] - [Restart] from the menu bar to restart SNMP Service.
Restarting PSA
1. Click [Start menu] - [Administrative Tools] - [Services].
2. Select [PRIMEQUEST Server Agent] in the right side of the window.
3. Select [Action] - [Restart] from the menu bar to restart PRIMEQUEST Server Agent.
How to confirm a trap destination setting
To confirm a trap destination setting, use the standard SNMP Service trap sent to restart SNMP Service in the above
step 8. You can confirm the correct trap setting by checking whether the trap was received.
Remarks
The operation performed in step 8 on the trap source machine restarts SNMP Service.
After that operation, a Cold Start trap is posted to the trap receiving application at the trap destination. Cold Start
is a standard SNMP Service trap.
snmptrapd runs on the Linux machine that is the trap destination to receive traps. snmptrapd outputs the following
message to the system log. Confirm that the Linux machine received the trap normally.
Aug 17 14:50:03 pq-server snmptrapd[2600]: 2005-08-17 14:50:03 \
pq-server.fujitsu.com
[192.168.0.162] (via 192.168.0.162) TRAP, SNMP v1, community \
public SNMPv2-SMI::
enterprises.211.1.31.1.2.100.3 Cold Start Trap (0) Uptime: 0:00:00.00
\: This indicates that there is no line feed.
6.4.5
Setting the destinations of traps and e-mail via the MMB
You can set the destinations of traps and e-mail via the MMB by using the MMB Web-UI.
For details on MMB trap destinations, see
. For details on e-mail destinations, see
Remarks
- Make settings only as needed.
- Operations management software needs these settings to manage events by partition.
6.4.6
Configuring the Windows Firewall
For operation with the Windows Firewall enabled, the following ports must be open to enable them to send and
receive data from the MMB.
PRIMEQUEST 1000 Series Installation Manual
CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E)
168
C122-E107-09EN
Содержание PRIMEQUEST 1000 Series
Страница 1: ...C122 E107 09EN FUJITSU Server PRIMEQUEST 1000 Series Installation Manual ...
Страница 2: ......
Страница 32: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 1 Installation Overview 4 C122 E107 09EN ...
Страница 44: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 2 Preparing for Main Unit Installation 16 C122 E107 09EN ...
Страница 260: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX A Lists of Settings Links 232 C122 E107 09EN ...
Страница 284: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation 256 C122 E107 09EN ...
Страница 340: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server Windows 312 C122 E107 09EN ...
Страница 344: ......