5.7
Configuring Service Life Monitoring by RAS Support Service
For the use of RAID cards and UPSs, configure the BBU (Battery Backup Unit) service life monitoring by RAS
Support Service.
SVIM automatically installs the RAS Support Service. For details on the manual installation and service life
monitoring setting procedures for RAS Support Service, see the
RAS Support Service User's Guide (for Linux or
Windows)
.
For details on SVIM, see the
ServerView Installation Manager
.
5.7.1
BBU service life monitoring for a RAID card
The BBU on a RAID card is a service life component. RAS Support Service performs service life monitoring.
When starting, RAS Support Service checks for the RAID cards that have a BBU in order of PCI bus number,
according to ServerView RAID information. It will monitor those RAID cards.
RAS Support Service performs service life monitoring and sends messages for replacement notification at the
following times.
TABLE 5.2 Message for advance notification of replacement and replacement notification message
(RAID card)
Start time for sending messages for advance notification
of replacement
Time for sending replacement notification
message
After about 2 years from the start of use or replacement
of the battery unit
After about 3 years
Operations
1. Start the GUI of RAS Support Service.
- Windows: Log in to the operating system. Start the GUI.
- Linux: Open a Web browser. Access the specified URL. Log in.
For details on operations, see the
RAS Support Service User's Guide (for Linux or Windows)
.
2. The Service Life Component Names list on the Component Service Life Information and Settings screen of
RAS Support Service displays [Battery (RAID_Card#xx)] in order of PCI bus number.
You can enter a value (for a RAID card) in the Mounting Dates list to enable battery service life monitoring.
In the Mounting Dates list, enter the mounting dates of the RAID cards for which to set service life monitoring.
Notes
Note the following points about BBU service life monitoring for a RAID card in the PRIMEQUEST 1800E2.
- Of the mounted RAID cards shown in
FIGURE 5.3 RAS Support Service screens (no BBU)
, the RAID card
without a BBU is not monitored by RAS Support Service.
FIGURE 5.3 RAS Support Service screens (no BBU)
PRIMEQUEST 1000 Series Installation Manual
CHAPTER 5 Work after Operating System Installation (PRIMEQUEST 1800E2)
123
C122-E107-09EN
Содержание PRIMEQUEST 1000 Series
Страница 1: ...C122 E107 09EN FUJITSU Server PRIMEQUEST 1000 Series Installation Manual ...
Страница 2: ......
Страница 32: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 1 Installation Overview 4 C122 E107 09EN ...
Страница 44: ...PRIMEQUEST 1000 Series Installation Manual CHAPTER 2 Preparing for Main Unit Installation 16 C122 E107 09EN ...
Страница 260: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX A Lists of Settings Links 232 C122 E107 09EN ...
Страница 284: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX B Manual PSA Installation and Uninstallation 256 C122 E107 09EN ...
Страница 340: ...PRIMEQUEST 1000 Series Installation Manual APPENDIX F Setting up the NTP Server Windows 312 C122 E107 09EN ...
Страница 344: ......