CHAPTER 2
Core Configuration
Installing Cables
2-75
FLASHWAVE 7500 Release 6.1
Equipment Installation
Fujitsu and Fujitsu Customer Use Only
FNC-7500-0061-200
Issue 1, May 2009
2.13.9
Installing RICC Cable (Optical Shelf)
This procedure provides instructions for connecting to the RICC ports on the Optical shelf
backplane.
lists pertinent information for these cables.
shows the cable connector pinouts.
Note:
RICC cables are only installed as needed with an asymmetric HUB node and are not part
of the equipment installation. For more information on symmetric and asymmetric HUB nodes,
refer to
System Description and Engineering,
Section 2.2, Core Configuration [p. 2-2]
Step
Task
1
Connect the RJ-45 connector on one end of the RICC cable (21-332-xxx) to Main Optical
shelf backplane connector CN24…CN26, CN28…CN30 or CN32…CN37.
Table 2-9: RICC Cable Information (Core Configuration)
Cable Part
Number
Backplane Connector
Number
Cable Description
Connector
Type
Cable Wire
Size
21-332-xxx
a
a
xxx = length in feet
CN24…CN26, CN28…CN30,
CN32…CN37 (Main and
Auxiliary Optical shelves)
RICC connection
RJ-45
24 AWG
Figure 2-41: Connector Pinouts, RICC Cable
1
2
3
4
5
6
7
8
TXP
TXN
RXP
RXN
m1
71
4a
u_
1
Revision 1, June 2009