CHAPTER 2
Core Configuration
Installing Fans and DCM Shelf
2-35
FLASHWAVE 7500 Release 6.1
Equipment Installation
Fujitsu and Fujitsu Customer Use Only
FNC-7500-0061-200
Issue 1, May 2009
2
Install the SFD3 shelf in the bottom of the rack that contains the Optical shelf (if space
permits) or in a rack adjacent to the Optical shelf. Secure the shelf to the rack using three rack
mounting screws on each side of the shelf.
Note:
If hole alignment does not permit three screws on each side, it is acceptable to secure the shelf
with only two screws on each side.
3
If the shelf came without the DCM units already installed:
a.
Locate the appropriate units to be installed and remove them from their protective ESD
packaging.
b.
Loosen the thumbscrews and remove the faceplate/cover from the shelf.
c.
Carefully slide each DCM unit into the appropriate shelf slot.
d.
Replace the cover and tighten the thumbscrews to secure each unit in the shelf.
This procedure is complete.