1-5. INDOOR FAN CONTROL
1. Fan speed
( Table 5 : Indoor fan speed )
Operation mode Air flow mode Speed (rpm)
Cooling /
Heating
Dry
X : 780
J : 680
Hi
Powerful
Powerful
Me+
Me
Lo
Quiet
Cool air prevention
Hi
Me
Lo
Quiet
S-Lo
1370
1520
1150
1260
950
780
600
1370
1520
950
1150
780
540
2. FAN OPERATION
The airflow can be switched in 5 steps such as Auto, Quiet, Low, Med, High, while the indoor fan only runs.
4. DRY OPERATION
The airflow can be switched in 5 steps such as Auto, Quiet, Low, Med, High, while the indoor fan only runs.
3. COOLING OPERATION
Switch the airflow [Auto], and the indoor fan motor will run according to a room temperature, as shown in Fig.7.
On the other hand, if switched in [High] [Quiet], the indoor motor will run at a constant airflow of [Cool]
operation modes Quiet, Low, Med, High, as shown in Table 5.
( Fig.5 : Airflow change - over ( Cooling : Auto ) )
When the room
temperature rises
When the room
temperature drops
Tr : Room temperature
Ts : Setting temperature
Tr-Ts > 4
°
F
(2
°
C)
(2
°
C)
=
2
°
F
(1
°
C)
> Tr-Ts
4
°
F > Tr-Ts > 2
°
F
(1
°
C)
=
Tr-Ts > 5
°
F
(2.5
°
C)
=
3
°
F
(1.5
°
C)
> Tr-Ts
5
°
F
(2.5
°
C)
> Tr-Ts > 3
°
F
(1.5
°
C)
=
Hi
Me
Lo
01-04
Содержание AOU30RLXEH
Страница 4: ...1 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Страница 36: ...R410A WALL MOUNTED type INVERTER 2 TROUBLE SHOOTING ...
Страница 89: ...R410A WALL MOUNTED type INVERTER 3 APPENDING DATA ...
Страница 96: ...3 1 3 Procedures to change the Function Setting 03 07 ...
Страница 120: ...3 3 17 Suenaga Takatsu ku Kawasaki 213 8502 Japan Jun 2016 Printed in Japan ...