CONTENTS
1. DESCRIPTION OF EACH CONTROL OPERATION
1-1 COOLING OPERATION............................................................................................
01-01
1-2 HEATING OPERATION.............................................................................................
01-02
1-3 DRY OPERATION.....................................................................................................
01-02
1-4 AUTO CHANGEOVER OPERATION........................................................................
01-03
1-5 INDOOR FAN CONTROL..........................................................................................
01-04
1-6 OUTDOOR FAN CONTROL......................................................................................
01-07
1-7 LOUVER CONTROL..................................................................................................
01-08
1-8 COMPRESSOR CONTROL.......................................................................................
01-09
1-9 TIMER OPERATION CONTROL...............................................................................
01-10
1-10 ELECTRONIC EXPANSION VALVE CONTROL....................................................
01-14
1-11 TEST OPERATION CONTROL...............................................................................
01-14
1-12 PREVENT TO RESTART FOR 3 MINUTES............................................................
01-15
1-13 4-WAY VALVE EXTENSION SELECT....................................................................
01-15
1-14 AUTO RESTART.....................................................................................................
01-15
1-15 MANUAL AUTO OPERATION.................................................................................
01-15
1-29 PUMP DOWN...........................................................................................................
01-20
1-16 COMPRESSOR PREHEATING...............................................................................
01-16
1-17 POWERFUL OPERATION.......................................................................................
01-16
1-19 ECONOMY OPERATION.........................................................................................
01-16
1-30 DEFROST OPERATION CONTROL.......................................................................
01-21
1-31 OFF DEFROST OPERATION CONTRO.................................................................
01-23
1-18 MINIMUM HEAT OPERATION................................................................................
01-16
1-32 VARIOUS PROTECTIONS......................................................................................
01-24
1-25 FORCED COOLING OPERATION...........................................................................
01-19
1-26 HEAT INSULATION CONDITION (When using the wireless RC)...........................
01-19
1-27 THERMO CONTROL (FOR INDOOR UNIT SENSOR)...........................................
01-19
1-28 THERMO CONTROL (FOR WIRED REMOTE SENSOR).......................................
01-19
1-20
COMPRESSOR STOP OPERATION........................................................................
01-17
1-21 LOW NOISE OPERATION.......................................................................................
01-17
1-22 HUMAN SENSOR OPERATION..............................................................................
01-18
1-23 BASE HEATER OPERATION..................................................................................
01-18
1-24 PEAK CUT OPERATION..........................................................................................
01-18
1-33 DESCRIPTION OF DISPLAY UNIT.........................................................................
01-27
1-33-1 LAYOUT OF DISPLAY UNIT............................................................................
01-27
1-33-2 DISPLAY MODE...............................................................................................
01-28
1-33-3 ERROR HISTORY MODE.................................................................................
01-29
Содержание AOU30RLXEH
Страница 4: ...1 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Страница 36: ...R410A WALL MOUNTED type INVERTER 2 TROUBLE SHOOTING ...
Страница 89: ...R410A WALL MOUNTED type INVERTER 3 APPENDING DATA ...
Страница 96: ...3 1 3 Procedures to change the Function Setting 03 07 ...
Страница 120: ...3 3 17 Suenaga Takatsu ku Kawasaki 213 8502 Japan Jun 2016 Printed in Japan ...