-13°F (-25°C)
110 rps
-4°F (-20°C)
-4°F (-20°C)
5°F (-15°C)
Cooling
Heating
1-20. COMPRSSOR STOP CONTROL
When the detection value of outdoor temperature sensor is lower than temperature
in the table below, the compressor is stopped.
( Table 19 : Operation temperature of compressor stop control )
Operation temperature
Maximum frequency
Release temperature
Temperature
1-21. LOW NOISE OPERATION
Low Noise mode
LEVEL 1
LEVEL 2
Outdoor fan speed
[rpm]
Compressor
speed
[rps]
The compressor speed and the outdoor unit fan sp
Capacity priority mode
(1) Operation condition
The function setting is set the “1” for the capacity priority mode.
When detect the shortage capacity or enough capacity condition continuous 30 minute,
the mode is upped or downed for 1 step.
(2) Check the capacity condition
30min
Enough
30min
Enough
30min
Shortage
30min
Shortage
(3) Operation
Automatic switching 1
Level 1 setting
Automatic switching 2
Level 2 setting
Shortage
Enough
eed are limited to reduce the operation noise
by External Input.
During the LOW NOISE OPERATION, "CURRENT OVERLOAD OPERATION", "ECONOMY OPERATION"
and "PEAK CUT OPERATION" are effective, and the outdoor unit operates by lowest current of them.
However, during the DEFROST OPERATION, the compressor operates by the speed for DEFROST
OPERATION.
( Table 20 : Detail of low noise operation )
520/520
50
46
36
37
Normal
operation
*The performance drops when operating in the
LOW NOISE OPERATION
.
Low noise
mode 2
Low noise
mode 1
30min
Enough
30min
Shortage
Normal
operation
Low noise
mode 1
Required compressor speed > Limited compressor speed of low noise mode
Required compressor speed < Limited compressor speed of low noise mode
(Upper / Lower)
Cooling
Cooling
Heating
Heating
01-17
Содержание AOU30RLXEH
Страница 4: ...1 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Страница 36: ...R410A WALL MOUNTED type INVERTER 2 TROUBLE SHOOTING ...
Страница 89: ...R410A WALL MOUNTED type INVERTER 3 APPENDING DATA ...
Страница 96: ...3 1 3 Procedures to change the Function Setting 03 07 ...
Страница 120: ...3 3 17 Suenaga Takatsu ku Kawasaki 213 8502 Japan Jun 2016 Printed in Japan ...