Heating mode
F zone
E zone
D zone
C zone
B zone
A zone
66.2°F
(19°C)
32.0°F
(0°C)
5.0°F
(-15°C)
-13.0°F
(-25°C)
41.0°F
(5°C)
Model name
Outdoor temperature zone
Limitation of compressor
frequency
AOUH09LUAS1
A zone
37 rps
B zone
37 rps
C zone
36 rps
D zone
15 rps
E zone
15 rps
F zone
1 rps
AOUH12LUAS1
A zone
34 rps
B zone
34 rps
C zone
34 rps
D zone
15 rps
E zone
14 rps
F zone
14 rps
AOUH18LUAS1
A zone
30 rps
B zone
30 rps
C zone
30 rps
D zone
13 rps
E zone
10 rps
F zone
10 rps
1-5. Compressor frequency limitation by outdoor temperature