7. Various control
7-1. Auto restart
→hen the power was interrupted by a power failure etc. during operation, the operation contents at
that time are memorized and when the power is recovered, operation is automatically started with
the memorized operation contents.
Operation contents memorized when the power is interrupted
Operation mode
Setting temperature
Fan mode setting
Timer mode and set time (set by wireless remote controller)
Airflow direction setting
Swing
ECONOM↔ operation
MIN. HEAT operation
7-2. MIN. HEAT operation
MIN. HEAT operation performs as below setting when pressing MIN. HEAT button.
Operation mode
Heating
Setting temperature
50°F (10°C)
Fan mode
AUTO
LED display
Economy
Defrost operation
Operate as normal
7-3. ECONOMY operation
The ECONOM↔ operation starts by pressing ECONOM↔ button on the remote controller.
The ECONOM↔ operation is almost the same operation as below settings.
Mode
Cooling/Dry
Heating
Target temperature
Setting tempe2°F (1°C)
Setting temperature -2°F (1°C)
7-1. Auto restart
- (04-25) -
7. Various control
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
Содержание ACUH09LUAS1
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2021 04 02 SR_CH01_AU021EF_01 ...
Страница 14: ...2 2 Outdoor unit 01 8 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Страница 15: ...2 TECHNICAL DATA AND PARTS LIST 2021 04 02 SR_CH02_AU021EF_01 ...
Страница 45: ...3 TROUBLESHOOTING 2021 04 26 SR_CH03_AU021EF_01 ...
Страница 48: ......
Страница 105: ...4 CONTROL AND FUNCTIONS 2021 04 26 SR_CH04_AU021EF_01 ...
Страница 143: ...5 FILED WORKING 2021 04 26 SR_CH05_AU021EF_01 ...