3. Fan control
Tr: Room temperature
Ts: Setting temperature
3-1. Indoor fan control
¢
Fan speed
Indoor fan speed is defined as below.
Operation mode
Fan mode
Speed (rpm)
ACUH09LUAS1
ACUH12LUAS1
ACUH18LUAS1
Heating
HIGH
590
650
830
MED+
570
620
770
MED
540
580
730
LO→
490
520
630
QUIET
440
460
500
Cool air
prevention
400
400
400
S-LO→
300
300
300
Cooling/Fan
HIGH
590
650
790
MED
540
580
630
LO→
490
520
540
QUIET
440
460
460
Soft quiet
400*
1
400*
1
400*
1
S-LO→
300*
2
300*
2
300*
2
Dry
↓ zone: 440
J zone: 440
↓ zone: 460
J zone: 460
↓ zone: 460
J zone: 460
*1: Fan mode only
*2: Cooling mode only
¢
Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LO→, MED, HIGH while indoor unit fan
only runs.
→hen fan mode is set at AUTO, it operates on MED fan speed.
¢
Cooling operation
Switch the airflow AUTO, and indoor fan motor will run according to room temperature, as below.
On the other hand, if switched in HIGH—QUIET, indoor motor will run at a constant airflow of COOL
operation modes QUIET, LO→, MED, HIGH as shown in “Fan speed” above.
Airflow change over (Cooling: Auto)
When room
temperature rises
When room
temperature drops
Tr - Ts ≥ 4°F (2
°C)
HIGH mode
MED mode
LOW mode
4°F (2
°C)
> Tr - Ts ≥ 2°F (1
°C)
2°F (1
°C) > Tr - Ts
Tr - Ts ≥ 5°F (2.5
°C)
5°F (2.5
°C)
> Tr - Ts ≥ 3°F (1.5
°C)
3°F (1.5
°C) > Tr - Ts
3-1. Indoor fan control
- (04-10) -
3. Fan control
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
Содержание ACUH09LUAS1
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2021 04 02 SR_CH01_AU021EF_01 ...
Страница 14: ...2 2 Outdoor unit 01 8 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Страница 15: ...2 TECHNICAL DATA AND PARTS LIST 2021 04 02 SR_CH02_AU021EF_01 ...
Страница 45: ...3 TROUBLESHOOTING 2021 04 26 SR_CH03_AU021EF_01 ...
Страница 48: ......
Страница 105: ...4 CONTROL AND FUNCTIONS 2021 04 26 SR_CH04_AU021EF_01 ...
Страница 143: ...5 FILED WORKING 2021 04 26 SR_CH05_AU021EF_01 ...