1-5. Compressor frequency limitation by outdoor temperature
The minimum compressor frequency is limited by outdoor temperature as below.
•
Cooling/Dry mode
F zone
E zone
D zone
C zone
B zone
A zone
14.0°F
(-10°C)
32.0°F
(0°C)
50.0°F
(10°C)
66.2°F
(19°C)
100.4°F
(38°C)
Model name
Outdoor temperature zone
Limitation of compressor
frequency
AOUH09LUAS1
A zone
35 rps
B zone
35 rps
C zone
35 rps
D zone
15 rps
E zone
15 rps
F zone
36 rps
AOUH12LUAS1
A zone
37 rps
B zone
37 rps
C zone
37 rps
D zone
28 rps
E zone
1 rps
F zone
22 rps
AOUH18LUAS1
A zone
33 rps
B zone
33 rps
C zone
33 rps
D zone
25 rps
E zone
10 rps
F zone
20 rps