69
Splice Menu
1-5.
Manual Splice Mode
This mode is to manually align and splice fibers. The following procedure is required,
and is different from standard automatic splicing.
(1) Press SET key to drive the fibers forward. The fibers stop moving forward at the
Gapset position.
(2) Select a motor to be manually moved by pressing Up/Down Arrow key. The name
of the motor to be moved is displayed in the monitor. Motor speed can be selected
"fast" or "slow" by pressing Enter key.
(3) Press Up/Down Arrow key to move the selected motor and drive the fibers forward
or backward.
(4) After manual alignment is completed, press ARC key to arc and splice the fibers.
Motor
Up Arrow key
Down Arrow key
ZL/ZR Forward
Backward
X/Y Upward
Downward
Focus X
Focus Y
Lens moves nearer fiber.
Lens moves away from fiber.
• The splicer beeps if motor stroke comes to its limit and the motor stops. Press
the opposite arrow key to move the motor again.
• Display messages can be erased by pressing Menu key. The message can be
displayed by pressing Menu key again.