48
Basic Operation
10.
Removing spliced fiber
(1) Open lids of tube heater.
(2)
Open wind protector.
(3) Hold left fiber with left hand at the edge of wind
protector and open left sheath clamp or fiber
holder lid.
(4) Open right sheath clamp or fiber holder lid.
(5) Hold right fiber with right hand, and remove
spliced fiber from the splicer.
11.
Heating protection sleeve
(1)
Transfer fiber with protection sleeve to tube heater. Protection sleeve is placed in the
center of the tube heater.
(2) Place fiber with protection sleeve in tube heater. Slide spliced fiber slowly to the
right until left hand reaches the edge of the tube heater. While placing it in the tube
heater, apply some tension on the fiber so the tube heater lids automatically close. .
Then heating starts automatically as soon as the tube heater is closed.
• To disable the “Auto Start” function, set [Auto Start] in [Heater Menu] to turning
off. See page 83 [Auto Start]. Press HEAT key to start tube heating when “Disable”
is selected.
• Keep on holding fiber until fiber is
completely transferred to tube
heater.
•Make sure the splice point is located
at the center of the protection
sleeve.
•Make sure the strength member in
the protection sleeve is placed
downwards.
Hold left fiber with left hand at the
edge of the splicer.
Sheath Clamp
Fiber Holder
Slide spliced fiber to the right until left
hand reaches the edge of tube heater.