48
TURBOTEST 500B User’s Guide
Figure 7-1. OPM Reference Setup.
Section 7: Testing with the TURBOTEST 500B, OPM, and OLS
If only one TURBOTEST 500B unit is available for testing, the Optical Power Meter (OPM) and Optical
Light Source (OLS) may be used for performing optical loss tests on two fibers. The Optical Power
Meter and Light Source in the following examples are manufactured by Noyes, other manufacturers'
equipment can also be used.
Power Meter Reference Setup
Use the following procedures on the TURBOTEST 500B and the Optical Power Meter to perform optical
reference setup at a common site. The Optical Power Meter in this example is the Noyes OPM 5.
Refer to Figure 7-1 for a related Illustration.
Clean all fiber optic connectors before performing test procedures described below.
Do the following to the TURBOTEST 500B:
1 Enable the [OPM] test mode, then press the [MENU] key to display the [OPM MAIN MENU]
screen.
2 Use either [UP] or [DOWN] arrow key to highlight the [OTHER FUNCTIONS] option.
3 Press the [SELECT] soft key to access the [OTHER FUNCTIONS] screen.
TURBOTEST
500B
Optical
Power
Meter
Adapter
APC Connector
Reference Cable
5
12
Reference Cable
UPC Connector
Test Port
6
13
Adapter Cap