700- LT1-Man Rev 8 09 Feb 2021
Page 10/60
•
log onto the FTS360 Config App as a member of the Agency to which the station is assigned,
•
synchronize with FTS360, and remain logged on (Note: Synchronization occurs
automatically when logging onto the FTS360 Config App with an internet
connection)
Prior to going to the field and immediately upon return (or when internet connection is possible),
you should log on to the FTS360 Config App to synchronize with FTS360. Until synchronization
occurs, FTS360 will not be able to display data from that station.
IMPORTANT!
For FTS360 to recognize LT1 data it receives, the FTS360 Config App
MUST be synchronized with FTS360 after a field visit.
2.2.5
ADDING STATIONS
LT1 stations can only be added using the FTS360 Config App. LT1-GOES stations can be added using
FTS360 or the FTS360 Config App. The station will be added to the Agency which the user is logged
into.
IMPORTANT!
Ensure you are logged into the Agency into which you want to add the
new station.
The first time a station is connected to the FTS360 Config App, it’s identified by its serial number
unless the station was created in FTS360 and given a different name. Any configuration which
happens in the field will be saved to that station. Once synchronization happens, the station’s name
can be changed from the serial number to a user created name using the station edit function in
FTS360 or the FTS360 Config App.
2.2.6
RESETTING A STATION
Resetting a station is done through the Edit Station screen on the FTS360 Configuration App . There
are three options for resetting a station:
1) Reset PW:
This will reset the station to the default password. All settings and configurations
remain, however, no other user will be able to access the station until you sync your device with
FTS360.
2) Reset Station Config:
This returns the station to its factory default settings. All sensor and
telemetry configurations will be lost. The Station remains in FTS360 as part of the Agency and is
accessible. Sensor and telemetry configurations will have to be entered for data transmission.
The station retains its last saved name. All data logged prior to resetting the station
configuration is retained under the station’s name in FTS360. If the LT1 is reconfigured with new
telemetry and sensors, new data will be logged under the station’s name continuous with
previously logged data.